System components:
Volumetric scale:1/40
Height scale:1
Power scale:1/40
Number of loops:3
Coolant:Water
Pressure min:0 MPa
Pressure max:1 MPa
Temperature min:20 °C
Temperature max:200 °C
Power max:1.5 kW
Approx. volume:515 m3
Approx. width:6.4 m
Approx. length or height:25 m
Keywords General:
Keywords Others:
Hot Wire Anemometer (HWA)
Mass Spectrometer (uncertainty 1.50%)
Particle Image Velocimetry (PIV)
Thermocouple (uncertainty 0.5 C)
Vortex Flow Meters (uncertainty 1.10%)
SETH/PKL, Countermeasures for two types of PWR accidents
NEA/CSNI/R(2016)2 SETH/PANDA, Three-dimensional gas flow distributions relevant to in-reactor containments under accidents conditions
SETH-2, OECD/NEA SESAR Thermal-hydraulics Project
The Nuclear Energy Agency–Paul Scherrer Institut Computation Fluid Dynamics Benchmark Exercise
Relevance | Phenomenon |
---|---|
Steam Splurging | |
Stratified Hydrogen Concentrations with Jets |