Primary system volume:7.63 m3
Primary system pressure (max):15.5 MPa
Core flow area:0.165 m2
Scaling method:P-to-V(Kv)
Time scale:1
Volumetric scale:1/60
Height scale:0.5
Scaling approaches:
Number of loops:2
Number of single loops:1
HL inner diam.:130 mm
CL inner diam.:130 mm
Seal depth1.27 m
Number of combined intact loops:3
HL inner diam.:350 mm
CL inner diam.:350 mm
Number of FOR loops:1
Number:2
Fluid:1-phase
Coastdown:Inertia
Number of sim. fuel Rods:1300
Diameter:10.7 mm
Pitch:14.3 mm
Heated length:1.68 m
Max power:50 MW
Cladding:Stainless Steel
Heating method:Nuclear
Number:1
Type:U Tube
Num. tubes comb. loop:1845
Pressure:6 MPa
ID:10.2 mm
OD:12.7 mm
Pitch:19 mm
SCCRED example Reference Data Set - Pressurizer
LOFT/LP-LB-1, Loss of Fluid Test, Large-Break LOCA Experiment
LOFT/LP-FW-1, Loss of Fluid Test, PWR Response to Loss-of-Feedwater Transient
LOFT/LP-SB-1, Loss of Fluid Test, Small Hot Leg Break LOCA, Early Pump
LOFT/LP-SB-2, Loss of Fluid Test, Small Hot Leg Break LOCA, Delayed Pump
LOFT/LP-02-6, Loss of Fluid Test, 1st OECD Large Break Experiment
LOFT/LP-SB-3, Loss of Fluid Test, Cold Leg Break LOCA, No High Pressureinjection System (HPIS)
LOFT/LP-FP-1B, Loss of Fluid Test, Fission Product Release Experiment
LOFT/LP-FP-2, Loss of Fluid Test, Fission Product Release from Fuel
LOFT/L2-5, Loss of Fluid Test, 3rd NRC L2 Large Break LOCA Experiment
LOFT/L2-3, Loss of Fluid Test, 2nd NRC L2 Large Break LOCA Experiment
LOFT/L3-6, Loss of Fluid Test, 6th NRC L3 Small Break LOCA Experiment
LOFT/L9-3, Loss of Fluid Test, Anticipated Transients with Multiple Failures
LOFT/L6-7, Loss of Fluid Test, Anticipated Transients with Multiple Failures
LOFT/L3-7, Loss of Fluid Test, 7th NRC L3 Small Break LOCA Experiment
LOFT/L3-5, Loss of Fluid Test, 5th NRC L3 Small Break LOCA Experiment
LOFT/L8-2, Severe Core Transient Experiment
D L Reeder: LOFT System and Test Description, NUREG/CR-0247 (TRBE-1208) July, 1978
https://inis.iaea.org/search/searchsinglerecord.aspx?recordsFor=SingleRecord&RN=10438103
D B Jarrel, J M Divine: Experiment Data Report for LOFT Intermediate Break Experiment LS-1 and Severe Core Transient Experiment LS-2, NUREG/CR-2398
Ybarrondo L. J., Griffith P., Fabic S., McPherson G.D., 1974, Examination of LOFT scaling: 74-WA/HT-53, Proc. of 95th Winter Annual Meeting of the ASME, New York