PM-5 (IET facility)

Country:
Russian Federation
Organization:
IPPE - Institute of Physics and Power Engineering
Operating years:
1991 - 1994
Reference reactor:
VVER 1000-4L

Main characteristics

Primary system pressure (max):0.3 MPa

Height scale:0.2

Scaling approaches:

Loops

Number of loops:1

HL inner diam.:60 mm

CL inner diam.:60 mm

Primary pumps

Notes:

Pump: 5000 kg/h

Core

Number of sim. fuel Rods:70

Max power:0.35 MW

Rod surface temperature:800

References