Primary system pressure (max):16 MPa
Scaling method:P-to-V(Kv)
Time scale:1
Volumetric scale:1/300
Height scale:1
Scaling approaches:
Number of loops:2
Number of single loops:1
Number of combined intact loops:5
Notes:
Intact loop had a length of about 45 m and a diameter 60.5 mm. The broken loop with a diameter 38.4 mm had a length of about 7 m. The length of the intact loop amounted to 32 m, the diameter 60.5 mm.The broken loop had a length of 16 m and a diameter of 38.4 mm. ;; Intact loop had a U-shaped loop seal with a sinking part of 4.5 m and a rising part of 2.5 m. broken loop was equipped with the same U-shaped loop seal. 38.4 mm had a length of about 7 m
Notes:
Intact loop contains main circulation pump, heater and cooler
Number of sim. fuel Rods:7
Diameter:9.1 mm
Pitch:12.75 mm
Heated length:3.45 m
Max power:1 MW
Cladding:Zr+1%Nb
Heating method:Indirect
Axial power distribution:Uniform & Stepwise
"THERMALHYDRAULICS" seminar in Warsaw, 1988
research reports of EDO "Gidropress"
VALIDATION MATRIX FOR THE ASSESSMENT OF THERMAL-HYDRAULIC CODES FOR VVER LOCA AND TRANSIENTS, NEA/CSNI/R(2001)4, June 2001