Coolant:Water
Primary system volume:0.128 m3
Primary system pressure (max):25 MPa
Scaling method:P-to-V(Kv)
Time scale:1
Volumetric scale:1/3000
Height scale:1
Scaling approaches:
Number of loops:2
Number of single loops:1
HL inner diam.:25 mm
CL inner diam.:25 mm
Number of combined intact loops:3
HL inner diam.:56 mm
CL inner diam.:41 mm
Number of FOR loops:1
Number:2
Notes:
Primary pumps installed in bypasses of each loop
Number of sim. fuel Rods:19
Diameter:9.1 mm
Pitch:12.75 mm
Heated length:3.53 m
Max power:1.8 MW
Cladding:Stainless Steel
Heating method:Direct
Number:4
Type:U Tube
Num. tubes single loop:11
Num. tubes comb. loop:33
Pressure:13 MPa
ID:11 mm
OD:16 mm
Average Tube length:2.71 m
4 preprints, EREC, 1990, 1993, 1994
Research Report 3.397, EREC, 1992
2 conference papers, 1994
VALIDATION MATRIX FOR THE ASSESSMENT OF THERMAL-HYDRAULIC CODES FOR VVER LOCA AND TRANSIENTS, NEA/CSNI/R(2001)4, June 2001