Height scale:1
Number of simulated fuel rods:64
Heat method:Indirect
Pressure min:0.1 MPa
Pressure max:2 MPa
Temperature min:37 °C
Temperature max:97 °C
Power min:150 kW
Power max:350 kW
Keywords General:
Keywords Core:
Keywords Others:
Experimental investigation of cooling by top spray and bottom flooding of a simulated 64 rod bundle for a BWR; Part 1: Preliminary bottom flooding tests; STUDSVIK/RL-77/1, Sweden 1977
L. Nilsson, L. Gustavsson, R. Haryu: Experimental Investigation of Cooling by Top Spray and Bottom Flooding of a Simulated 64 Rod Bundle for a BWR, Part 2. Main Experiment with Modified Test Section. Studsvik/RL-78/59. June 1978.
http://www.iaea.org/inis/collection/NCLCollectionStore/_Public/10/491/10491865.pdf?r=1
S.O. Eriksson et al.: "Experiments with Counter Current Steam Flow in the Spray Cooling Test Facility GOTA,".Studsvik (In Swedish). Aktiebolager Atomenergi, AES-15, NORHAVĀS-030, March 1977.
BWR-ECC Investigations: Spray cooling heat transfer experiment in a full scale BWR bundle mock-up, STUDSVIK/E4-78164, Sweden 1978
Core spray cooling effectiveness in a modified BWR fuel bundle (63+1 rod) STUDSVIK/RL-78124, Sweden 1978 .
Relevance | Phenomenon |
---|---|
Counter Current Flow Limitation (CCFL) | |
ECC Bypass | |
Heat Transfer : Core | |
Phase separation | |
Quench Phenomena | |
Spray Cooling in Upper Head |